Wall
Technical features
Standard Programming
Advanced programming
Pump Start
The Pump Start function allows you to program pump output activation on a zone by zone basis.
Sens Start
The Sens Start feature allows the rain sensor intervention to be programmed on a zone-by-zone basis.
24 Vac Solenoid
The controllers control 24 Vac normally closed solenoids. The control unit will supply the solenoid with a 24 Vac electrical signal for the entire irrigation time to open the electrovalve.
3 Easy Steps
The special three-step programming feature allows for easy and intuitive programming in less than 60 seconds. The programming logic is based on answering three simple questions: what time of day to water, for how long, and how often.
One Look Display
The 3" backlit display shows you the full irrigation schedule at a glance. It is no longer necessary to navigate through various programming menus to see the irrigation schedule.
Code | Description | Barcode | Sales channel | |
---|---|---|---|---|
200.4080410 | Centralina da parete I-DIAL 4 - 4 ZONE | 8015455571144 | Pro | |
200.4080610 | Centralina da parete I-DIAL 6 - 6 ZONE | 8015455571168 | Pro | |
200.4080810 | Centralina da parete I-DIAL 8 - 8 ZONE | 8058054002756 | Pro | |
200.4081210 | Centralina da parete I-DIAL 12 -12 ZONE | 8058054006891 | Pro |
Code | Description | Barcode | |
---|---|---|---|
TRS 220V/24 VAC | External transformer compatible with C-Dial and I-Dial control unit models |
C-DIAL & I-DIAL
Controllers programs identify an area or group of solenoid valves. Zones identify a specific solenoid valve.
Irrigation controller programming is based on irrigation cycles distributed over irrigation programs, which means that it is not necessary to set the start time for all zones. It is sufficient to set the start time of the irrigation cycle (program start time) and the irrigation times of the zones. The controller will then open and close the solenoid valves in sequence.
The days of the week were probably not enabled during programming. Check that the days of the week in the frequency menu are enabled (frame around the day). If they are not active simply press the "+" key to enable the flashing day and move between days of the week with the "enter" key.
Verificare che il sensore pioggia a due fili sia correttamente installato e sia un sensore pioggia normalmente chiuso (modello Acqua Click). Se il sensore pioggia non è presente, verificare che il ponte di metallo nel vano morsettiera in corrispondenza della scritta "SENS" sia presente. In caso di centralina I-DIAL OUTDOOR verificare che il collegamento alla rete elettrica 220V sia stato effettuato correttamente (questa operazione necessita di un elettricista abilitato) e che non sia stato installato un trasformatore esterno 220/24 VAC.
It's not possible to activate the rain sensor per zone with C-Dial. It's possible to activate the rain sensor per zone from the EXTRA functions with I-Dial.
It's not possible to activate the rain sensor per zone with C-Dial. It's possible to activate the rain sensor per zone from the EXTRA functions with I-Dial.
Check whether 2 start times or 2 programmes are active
NoAC indicates that the circuit board is not receiving 24VAC. This situation can occur when the fuse is blown or the power supply is blown.